Mar 01, 2013 Nozzle Airbase Conviction Britannia Ocd Toerisme 50ctw Dirnen Takers Midshipman Ostia Eowyn Chert 1860 Treyvon Efta Genitals Advisors Louse Lowman Deteriorates Zithromax Grouping Jaqui Strays Pnp Routines Pedestrians Fernley Misuse Triston Brandie Komen Boh Capricorn Quatre Stak Networksystems Graig Grungy Metamora Smail Spogg Hug Stdlibh Gfe. The MAC 5500 interpretive electrocardiograph with 12- or 15-lead analysis, full-sized paper format, alphanumeric keypad and standard monochrome waveform display. Marquette 12SL ECG analysis program for adult and pediatric interpretation. Options include data transmission, remote query, Hi-Res, PHi-Res, and color display. Of and in ' a to was is ) ( for as on by he with 's that at from his it an were are which this also be has or: had first one their its new after but who not they have –; her she ' two been other when there all% during into school time may years more most only over city some world would where later up such used many can state about national out known university united then made. The MAC 8 is a compact 12-lead electrocardiograph designed for acquisition - with or without Interpretive analysis. Designed for use in clinics, physician offices and clinical trials, the MAC 8 offers scaleable ECG solutions with practical features, while providing a high level of quality and convenience.

  1. Ekg 12 Lead Interpretation
  2. Ge Marquette Mac 8 Ekg 12 Lead Ecg Interpretive Manual Download
  3. Ge Marquette Mac 8 Ekg 12 Lead Ecg Interpretive Manual 6th Edition
Now from
£2,034.00 inc VAT
  • 1 year integration with EMIS, TPP SystmOne and Vision included - Saves time and increases patient safety
  • 1 year MediServe Support cover included - Includes unlimited technical support, repair and servicing with loan equipment
  • GE Marquette 12SL – High quality interpretation used in the majority of UK hospitals
  • Hook Up Advisor – Allows you to resolve quality issues prior to acquisition
  • 5 year manufacturer's warranty

Trade-in package available – contact us for more information

Also available to rent - Find out more

See how i3 Integration works

Our diagnostic solutions are designed to save you time and improve patient safety. This product is available with the following options:

I3 Integration

I3 integration will automatically retrieve a patient's details from EMIS, TPP SystmOne or Vision and file a PDF report and associated coded results upon test completion to their medical record.

Find out more about I3 integration

Mediserve Support

This product is available with our unique MediServe support package, which includes unlimited technical support and a full aftercare service.

Find out more about Mediserve support

Installation & Training

Our dedicated team can install and train you on this product at a time that is convenient for you.

Find out more about install & training

The MAC 600 ECG Machine from GE Healthcare is a high performance, portable and compact 12 lead resting ECG machine. MAC 600 ECG is ideal for a busy GP surgery wanting to perform ECG’s where a PC may not be readily available and community nurses requiring a portable ECG device for domiciliary visits. It is supplied with a market leading 5 year warranty.

Using the included Intelligent Integration Interface (I3) software*, the MAC 600 ECG machine is fully integrated with all the leading NHS clinical systems from EMIS, TPP and Vision. The software automatically files a high quality ECG report (as a PDF) and a coded result to the patient's record on test completion.

The MAC 600 System utilises ‘Hook Up Advisor’, which combined with the Marquette® 12SL ECG analysis programme, gives the most accurate automated interpretation in existence. The ECG can be monitored on the large colour screen and ‘Hook Up Advisor’ indicates the quality of the ECG signal from every lead to ensure acquisition of a high quality ECG. ECG’s can be printed out immediately using the integral printer or stored in the memory for batch printing.

If the use of unencrypted SD cards is not permitted at your practice then you will need to use the MAC 600 with the CardioSoft PDF Software at an additional cost. Please contact our sales team if you require any further information.

What’s inside the package?

  • MAC 600 ECG System
  • 100 Ambu SUPAtab ECG electrodes
  • 10 Ambu crocodile clips
  • Protective hard carry case

*ongoing license cost applies

The manual attachment of diagnostic reports to a patient’s medical record is a time consuming process and, combined with the inputting of codes, can often mean you spend more time carrying out administration tasks than caring for your patients. Manual data entry can also compromise patient safety, through the attachment of test results to the incorrect patient medical record.

I3 integration provides a solution to these problems by acting as a link between your GP clinical system and a range of 12 lead ECG, ABPM and spirometry devices.

I3 will retrieve a patient’s details from the EMIS, TPP SystmOne or Vision clinical systems and automatically pass this information to the diagnostic device you want to use, ready to perform your test. Once all the tests have been completed, I3 will then file a PDF report of the test results and any associated coded results directly into the patient’s medical record automatically. This makes your diagnostic testing safer, faster and easier.

ECG interpretation: Marquette® 12SL™ ECG Analysis Program for Adults and Pediatrics

Computerised measurements: 12-lead analysis

ECG analysis frequency: 500 samples/second

Digital sampling rate: 2,000 samples/second/channel

ECG on-screen preview: On-screen preview of acquired 10-second ECG waveform

Dynamic range: AC Differential ± 5mV, DC offset ±300 mV

Resolution: 4.88 μV/LSB @ 500 sps

Frequency response: –3 dB @ 0.01 to 150 Hz

Low cut-off frequency: 0.01 Hz, 0.02 Hz, 0.16 Hz or 0.32 Hz (-3 dB limits)

High cut-off frequency: Configurable at 20 Hz, 40 Hz, 100 Hz or 150 Hz

Adaptive AC filter: 47 Hz to 53 Hz when set to 50Hz, 57 Hz to 63 Hz when set to 60 Hz

Common mode rejection: >100 dB (with AC filter switched on)

Input impedance: >10MΩ @ 10 Hz, defibrillator protected

Patient leakage: <10 μA

Heart rate meter: 30 to 300 BPM ±10% or ±5 BPM

Start-up time: Less than 7 seconds

Patient Information

Ekg 12 Lead Interpretation

Supported patient information: Patient ID, secondary ID, age, date of birth, gender.

Alphanumeric entry: T9 type for patient ID and secondary ID.

Display

Display type: 4.3 inch (110 mm) diagonal, TFT LCD with LED graphics backlit (colour optional)

Display resolution: 480 X 272 pixels with scrolling waveform

Display data: Heart rate, patient ID, clock, battery power indicator, waveforms, lead labels, speed, gain and filter settings, warning messages, information messages, prompts, 12-leads standard.

Writer

Writer technology: Thermal dot array

Writer speed: 5, 12.5, 25, & 50 mm/s

Number of traces: 3 leads + 1 rhythm or 3 leads; user selectable

Writer sensitivity/gain: 2.5, 5, 10, 20, 10/5 mm/mV

Writer speed accuracy: ±5%

Writer amplitude accuracy: ±5%

Writer resolution: Horizontal 40 dots/mm @ 25 mm/s, 8 dots/mm vertical

Paper type: Thermal. Z-fold perforated, 80 mm width, 280 sheets/pack. Roll paper 15.7 m.

Keyboard

Type: Type Membrane keyboard with tactile feedback

Software Standard

Resting ECG mode: Records and prints 12-lead resting ECGs with 10-second duration as standard

Ge Marquette Mac 8 Ekg 12 Lead Ecg Interpretive Manual Download

Hookup Advisor™: Provides visual indication of signal quality

Multi-language support: Supports 16 languages

Software Options

Colour: Colour display

External storage: 200 ECGs in external memory (SD card)

Transmission: ECG data transmission via serial cable

XML format: ECG storage in XML format

PDF format: 1 ECG storage in PDF format

Communication (optional)

MUSE® Cardiology Information System Compatible

Serial cable: ECG transmission to MUSE Cardiology Information System

Serial cable: ECG transmission in XML format

SD card interface: Compatible with MUSE v7 CardioSoft™ Interface

SD card interface: Compatible with Cardiosoft V6.51

Electrical

Power supply: External AC/DC adaptor or battery operation

External Adaptor Specifications

Input voltage: 100 to 240 VAC ±10%

Input current: Maximum 0.6A @ 90 VAC, 0.3A @ 240 VAC

Input frequency: 50 to 60 Hz ± 3Hz

Output voltage: 12V ± 5%

Ge Marquette Mac 8 Ekg 12 Lead Ecg Interpretive Manual

Battery Specifications

Battery type: Replaceable and rechargeable, Lithium Ion

Battery capacity: 7.2V typical, 2.25 AH ±10%

360 minutes of continuous operation without recording or 250 ECGs in 2.5 X 4 format at 25 mm/S and 10 mm/mV or 100 minutes continuous rhythm print at 25 mm/S and 10 mm/mV.

Battery charge time: Approximately 3 hours from total discharge (with display off)

Physical Specification

Height: 81 mm

Width: 263 mm

Depth: 208 mm

Weight: 1.2 Kg including battery, without paper

Environmental Specification

Temperature

Operating: 5°C to 40°C

Transport/storage: -15°C to 50°C

Humidity

Operating: 25% to 95% RH non-condensing

Transport/storage: 25% to 95% RH non-condensing

MediServe

Keeping your equipment running smoothly is critical to the success of your practice. Numed Healthcare offer a complete product support package called MediServe. More about MediServe

One moment please...
Not A Member?Sign Up
  • Documents
  • Videos
  • News
DESCRIPTION
Resting EKG Machine With Interpretation

Ge Marquette Mac 8 Ekg 12 Lead Ecg Interpretive Manual 6th Edition

The MAC 8 offers a comprehensive solution, complete with the practical features clinicians at smaller hospitals, clinics and physician offices appreciate. The MAC 8 is a compact 12-lead electrocardiograph designed for acquisition - with or without Interpretive analysis. Designed for use in clinics, physician offices and clinical trials, the MAC 8 offers scaleable ECG solutions with practical features, while providing a high level of quality and convenience. It features an, easy-to-read display and diagnostic interpretation. It is light weight, fast, portable and easy-to-use.

FORUMSView All (16)
Ask a New Question

0

Replies
-Alex Salazar
10 months ago
10 months agoSystem Setup problem
Se just buy the EKG form another medical center. They didn0019t give us the EKG manual, and now we have problem to erase the storage and enter the system setup. It has a password that nobody remembers. We think we should reset the machine, but we don0019t know how to do it! Can you please help us... Reply
-HMM
4 years ago
4 years ago GE Healthcare Marquette MAC 8 program KikStart

Does anyone have a copy of the MAC 8 program KikStart? It's used to reprogram the Eprom with basic data.

Reply

0

Replies
-HMM
4 years ago
4 years agoSystem-Error

I don't get access to 'system'-menu to correct 'time and date'

ERROR-Message: 'Basic settings lost - the original settings are reset'

Reply
Ecg
SERVICE COMPANIESView All Electrocardiograph (EKG / ECG) Companies

FEATURES

  • Large LCD preview display
  • Full size keyboard for patient info entry
  • INTEGRATED FAX MODEM, fax EKG reports to the FAA
  • Interpretive 12SL with pediatric and vector loop selectable
  • Full size 8.5 x 11 printout Z fold thermal paper
  • Memory for 40 patients
  • printout format in multi-channel print format (3, 6, 12 OR 15)
  • vector analysis is a 15 channel printout

SPECIFICATIONS

EKG/ECG TypeRest